BIOstone Filter Test Result

Jupiter Water Ionizer's Certificate of Analysis - Independent Water Testing

Use your browser's back button to navigate the water ionizer testing menu below.

General water analysis
Dissolved Metal water analysis
VOC common comtaminate analysis

ENTECH
A Division of Agri-Service Lab Inc.
6820 Kitimat Rd., Unit #4
Mississauga, ONT L5N 5M3
Phone: (905) 821-1112
Fax: (905) 821-2095

Sample Type: Water
Date Received: Nov 02, 2005
Date Analysed: Nov 02-09, 2005
Date Reported: Nov 10, 2005

Heartspring.net©2007

Entech, an independent water testing lab, has tested two separate Jupiter Melody water ionizers using both "before" and "after" water quality samples. In this test, an ionization cell, combined with the biostone carbon filter media, is shown to effectively reduce the presence of both lead and arsenic, two toxins prevously thought to be uneffected by water ionizers. This test also shows a reduction of sodium.

Parameter Units "Before"
Control
Sample
"After"
Jupiter
Melody
"After"
Jupiter
Melody
Duplicate
Nitrate g/mL 76.58 1.25 1.27
Nitrite g/mL 3.31 <0.02 <0.02
Nitrate(as N) g/mL 17.29 0.28 0.29
Nitrite(as N) g/mL 1 <0.006 <0.006
Ortho Phosphate g/mL 12.21 <0.05 <0.05
Fluoride g/mL 4.4 0.59 0.59
Carbonate g/mL - 9 10
Bicarbonate g/mL - 94 93
Total Anions meq/L - 3 3
Calcium g/mL 23.5 41 41
Magnesium g/mL 4.4 9.23 9.24
Sodium g/mL 21.97 14 14
Potassium g/mL 13.04 2.07 2.08
Aluminum g/mL 0.84 <0.05 <0.05
Lead g/mL 0.69 <0.004 <0.004
Iron g/mL 1.52 0.01 0.01
Manganese g/mL 0.34 0.002 0.001
Zinc g/mL 5.313 0.003 0.003
Total Cations meq/L - 3 3
Ion Balance % Difference - 7 6
Hardness (CaC03) g/mL - 140 140
pH - 7.41 9.03 9.04
Turbidity NTU 5.37 <0.25 <0.25
Alkalinity (CaC03) g/mL 25 104 104
Colour TCU - <1 <1
Total Dissolved Solids g/mL 308 208 218
Langelier Index - - 0.83 0.84
Conductivity mhos/cm 147 299 292
Ammonia (as N) g/mL 1.37 0.23 0.25
Sulphate g/mL 9.97 24.68 24.55

Jupiter Water Ionizer's Certificate of Analysis - Dissolved Metals - Lead Removal

In a specific test for dissolved metals, Entech laboratorties, shows the reduction of various metals present in the "before" control sample.

Parameter Maximum
Detectable
Testing
Level
"Before"
Control
Sample
"After"
Jupiter
Melody
"After"
Jupiter
Melody
Duplicate
Aluminum 30 438 <30 <30
Antimony 1 0.03 <1 <1
Arsenic 1 248 <1 <1
Barium 1 819 22.2 21.5
Beryllium 0.2 102 <0.2 <0.2
Boron 1 855 25.8 25.8
Cadmium 0.2 489 <0.2 <0.2
Calcium 20 23500 40967 40817
Chromium 10 374 <10 <10
Cobalt 2 818 <2 <2
Copper 2 341 2.62 2.4
Iron 5 346 6.2 5.9
Lead 4 209 <4 <4
Magnesium 10 4404 9226 9236
Manganese 1 139 1.1 1
Mercury 0.02 3.5 <0.02 <0.02
Molybdenum 7 575 <7 <7
Nickel 5 463 <5 <5
Potassium 100 13040 2071 2081
Selenium 1 15.7 <1 <1
Silver 1 185 <1 <1
Sodium 25 21970 13779 13809
Vanadium 5 1048 <5 <5
Zinc 2 273 3 3

Tests used - ICP - AES, CV - AAS, Hy - AAS (< symbol, less than)

Filtering Common Contaminants Found in Drinking water

In this test, a specially concocted “brew” containing excessive quantities of every commonly detected dangerous chemical found in drinking water was passed through a Jupiter water ionizer. The results show that contaminants were reduced in most cases to levels undetectable by the performing labs.

 

Independent Test Laboratories:

The follow laboratories have been involved with this test of the Jupiter's water ionizer cell technology.

  • Seoul Metropolitan Government Institute of Health and Environment, Korea
  • Mizutek, USA
  • Microbac Laboratories, USA
  • Brandywine Science Center
Contaminant Standard mg / litre Result mg / litre
KmnO4 10 2.7
Lead 0.05 Not Detectible
Fluoride 1.5 Not Detectible
Arsenic 0.05 Not Detectible
Cyanide 0.01 Not Detectible
Mercury 0.001 Not Detectible
Selenium 0.01 Not Detectible
Chromium (6+)0.05 Not Detectible
Cadmium 0.01 Not Detectible
Phenol 0.005 Not Detectible
Diazinon 0.02 Not Detectible
Malathion 0.25 Not Detectible
Parathion 0.06 Not Detectible
Fenitrothion 0.04 Not Detectible
1,1,1 Trichloroethane 0.1 Not Detectible
Tetrachloroethylene 0.03 Not Detectible
Dichloromethane 0.02 Not Detectible
Benzene 0.01 Not Detectible
Xylene 0.5 Not Detectible
1,1 Dichloroethylene 0.03 Not Detectible
Carbon Tetrachloride 0.002 Not Detectible
Methylene Chloride 25.0ppm 5.0ppm
Nitrate 10 1.82
Iron 0.3 <0.02
Manganese 0.05 <0.02
Sodium 20 8